Melanotan I lot KB-34289 certificate of analysis
10 mg vial. Tested by ILS Laboratories: purity 97.55% by HPLC-UV, identity confirmed by HPLC-RTM, net content 10.13 mg. Reported September 12, 2026.
Sample summary
| Product | Melanotan I 10 mg |
|---|---|
| Lot | KB-34289 |
| Purity (HPLC-UV) | 97.55% |
| Identity (HPLC-RTM) | Confirmed |
| Net content | 10.13 mg (+1.3% vs. label) |
| Appearance | Good (visual) |
| Endotoxin | Not tested for this lot |
| Microbial analysis (PCR) | Not tested for this lot |
Laboratory record
| Testing laboratory | ILS Laboratories |
|---|---|
| Client on certificate | Klow.bio |
| Accession number | ACC-2026-18994 |
| Certificate number | COA-2026-KDMU29 |
| Lab verification access code | AG2LHQYW |
| Received by lab | September 9, 2026 |
| Reported | September 12, 2026 |
| Release specification | Purity ≥95%; identity confirmed |
| Against stated specification | Meets |
The client listed on the certificate, Klow Labs LLC (klow.bio), is the company that operates MT1 Peptide Co..
Analytical results and methods
| Test | Method | Result |
|---|---|---|
| Identity | HPLC retention-time comparison with a reference standard (HPLC-RTM) | Confirmed |
| Purity | HPLC with UV detection (area percent) | 97.55% |
| Net content | Quantitation by the laboratory | 10.13 mg |
| Bacterial endotoxin | Limulus amebocyte lysate (USP <85>) | Not tested |
| Microbial DNA | Polymerase chain reaction (PCR) for common microbial contaminants | Not tested |
| Fentanyl | Immunoassay, 50 ng/mL cutoff | Not detected |
Verify this certificate
Accession number ACC-2026-18994, Certificate number COA-2026-KDMU29.
- Find the lot number on your vial. It is printed on the label, for example KB-34289.
- Look it up. Enter it at mt1peptide.bio/verify, or open the matching lot in the COA archive.
- Check the lab's own record. Go to portal.ils-lab.com (or scan the QR code on the certificate) and enter the lot's verification access code, listed on its lot page, to view the laboratory's own copy of the certificate.
- Compare the details. Lot number, the laboratory’s reference numbers, purity and dates should match exactly.
What a certificate of analysis does and doesn't show
- A COA reports the identity, purity and content of the specific sample tested, on its test date. Results apply to that lot only.
- HPLC purity measures the main peak relative to other detected components. It does not identify the peak on its own; the separate identity test (HPLC retention-time match) does that.
- A retention-time match shows the main peak behaves like the reference standard under one method. It is not a mass or structure measurement.
- Endotoxin and microbial results apply only where those tests appear on the certificate. Lots without them are marked "Not tested".
- A certificate does not establish stability after the test date or suitability for any particular purpose.
Other Melanotan I lots
| Lot | Vial size | Net content | Purity (HPLC-UV) | Identity (HPLC-RTM) | Endotoxin (LAL) | Microbial (PCR) | Reported | COA |
|---|---|---|---|---|---|---|---|---|
| KB-34289 | 10 mg | 10.13 mg | 97.55% | Confirmed | Not tested | Not tested | View lot KB-34289 |
Testing laboratory: ILS Laboratories. Release specification: purity ≥95% by HPLC-UV with identity confirmed by HPLC retention-time match against a reference standard. Results apply only to the lot listed. Certificates list the testing client as Klow.bio / Klow Labs LLC, the company that operates MT1 Peptide Co..
Buy MT1
10 mg vials. Current lot KB-34289 tested at 97.55% purity with identity confirmed by HPLC retention-time match against a reference standard. Current purchasing is available through Klow.bio.